POWER HOLDUP | |
---|---|
FORM FACTOR | 149x95x45mm, 149x95x45mm with LEDs |
CM-4012F0 AER SERIES | MANAGED AIRCRAFT SWITCH
$0.00
The CM-4012F0 AER Series is OnTime Networks product line of ruggedized managed gigabit Ethernet switches specifically designed to operate reliably in harsh climates and noisy electrical demanding environments of military aircraft. The Aircraft Switches are designed and tested to withstand extreme shock and vibration, wide temperatures and humidity, dust, and water exposure, including noisy EMI, and dirty power. The CM-4012-AER is qualified for temperatures of -55. to +85C, 85.000ft altitude, and provides 250ms hold-over capability.
Key Features
Product Data
- 3xMighty Mouse 37 pins connectors for 12×10/100/1000Base-T ports
- 28VDC (22-32VDC)
- Approved for military environmental and EMC requirements
- PTP 1588 Transparent Clock (TC) with PTP version translation (v1/v2) support
- NTP server
- Network redundancy based on MSTP/RSTP/STP
- Network management: Web, telnet, CLI and SNMP v1/v2/v3
- Multicast filtering: IGMP snooping or static multi-cast filters
- IEEE802.1Q VLAN
- Event notification: through Syslog and SNMP trap
- Wide operating temperature range
- Enhanced Watchdog features
- Port mirroring
- IEEE802.1x, access control
- Event notification through Syslog and SNMP trap
<table width=”729″>
<tbody>
<tr>
<td colspan=”3″ width=”716″><span style=”color: #000000;”>Switch protocols</span></td>
</tr>
<tr>
<td width=”240″><span style=”color: #000000;”>Standards</span></td>
<td colspan=”2″ width=”489″><span style=”color: #000000;”>IEEE 802.3x for Flow control</span>
<span style=”color: #000000;”>IEEE 802.3ad for LACP (Link Aggregation Control Protocol) IEEE 802.1D for STP (Spanning Tree Protocol)</span>
<span style=”color: #000000;”>IEEE 802.1p for COS (Class of Service) IEEE 802.1Q for VLAN Tagging</span>
<span style=”color: #000000;”>IEEE 802.1w for RSTP (Rapid Spanning Tree Protocol) IEEE 802.1s for MSTP (Multiple Spanning Tree Protocol) IEEE 802.1X for Authentication</span>
<span style=”color: #000000;”>IEEE 802.1AB for LLDP (Link Layer Discovery Protocol)</span>
<span style=”color: #000000;”>IEEE 1588 (PTPv1 and PTPv2)</span></td>
</tr>
<tr>
<td width=”240″><span style=”color: #000000;”>MAC table</span></td>
<td colspan=”2″ width=”489″><span style=”color: #000000;”>8192 MAC addresses</span></td>
</tr>
<tr>
<td width=”240″><span style=”color: #000000;”>Priority queues</span></td>
<td colspan=”2″><span style=”color: #000000;”>8</span></td>
</tr>
<tr>
<td width=”240″><span style=”color: #000000;”>Switch fabric properties</span></td>
<td colspan=”2″ width=”489″><span style=”color: #000000;”>Store-and-forward and full wire speed on all ports</span></td>
</tr>
<tr>
<td width=”240″><span style=”color: #000000;”>Security Features</span></td>
<td colspan=”2″ width=”489″><span style=”color: #000000;”>Enable/disable ports, MAC based port security</span></td>
</tr>
<tr>
<td width=”240″></td>
<td colspan=”2″ width=”489″><span style=”color: #000000;”>Port based network access control (802.1x)</span>
<span style=”color: #000000;”>VLAN (802.1Q ) to segregate and secure network traffic. Radius centralized password management</span>
<span style=”color: #000000;”>SNMPv3 encrypted authentication and access security</span></td>
</tr>
<tr>
<td width=”240″><span style=”color: #000000;”>Management</span></td>
<td colspan=”2″ width=”489″><span style=”color: #000000;”>HTTP/HTTPS, telnet/SSH, CLI and SNMP v1/v2/v3</span></td>
</tr>
<tr>
<td width=”240″><span style=”color: #000000;”>Built-in test</span></td>
<td colspan=”2″ width=”489″><span style=”color: #000000;”>Built-in test procedure performed at boot time. Continuous BIT procedure when</span>
<span style=”color: #000000;”>device is powered</span></td>
</tr>
<tr>
<td width=”240″><span style=”color: #000000;”>Other protocols</span></td>
<td colspan=”2″ width=”489″><span style=”color: #000000;”>IGMP snooping (up to 1024 multicast filters)</span>
<span style=”color: #000000;”>Static multicast filter setting Port rate limiting</span>
<span style=”color: #000000;”>DHCP</span>
<span style=”color: #000000;”>TOS/Diffserv supported</span>
<span style=”color: #000000;”>Quality of Service (802.1Q) for real-time traffic VLAN (802.1Q) with VLAN tagging and MVR</span>
<span style=”color: #000000;”>Port configuration, status, statistics, monitoring, security</span></td>
</tr>
<tr>
<td colspan=”3″ width=”716″><span style=”color: #000000;”>Connectors</span></td>
</tr>
<tr>
<td width=”240″><span style=”color: #000000;”>Power connector</span></td>
<td colspan=”2″ width=”489″><span style=”color: #000000;”>10 pin MMP (2M 801-011-07ZNU7-10PA), screw</span></td>
</tr>
<tr>
<td width=”240″><span style=”color: #000000;”>Connector spacing</span></td>
<td colspan=”2″ width=”489″><span style=”color: #000000;”>According to MIL-STD-1472F</span></td>
</tr>
<tr>
<td colspan=”3″ width=”716″><span style=”color: #000000;”>Data Zeroization Support</span></td>
</tr>
<tr>
<td width=”240″><span style=”color: #000000;”>Data Zeroization</span></td>
<td colspan=”2″ width=”489″><span style=”color: #000000;”>To erase Non-Volatile Flash Memory and Restore Board to Factory Default Config-</span>
<span style=”color: #000000;”>uration. Available via HTTP and CLI</span></td>
</tr>
<tr>
<td colspan=”3″ width=”716″><span style=”color: #000000;”>Power</span></td>
</tr>
<tr>
<td width=”240″><span style=”color: #000000;”>Power Consumption (Typ.)</span></td>
<td colspan=”2″><span style=”color: #000000;”>12</span></td>
</tr>
<tr>
<td width=”240″><span style=”color: #000000;”>Overload Current Protection</span></td>
<td colspan=”2″ width=”489″><span style=”color: #000000;”>Yes</span></td>
</tr>
<tr>
<td width=”240″><span style=”color: #000000;”>Reverse Polarity Protection</span></td>
<td colspan=”2″ width=”489″><span style=”color: #000000;”>Yes</span></td>
</tr>
<tr>
<td width=”240″><span style=”color: #000000;”>Power input</span></td>
<td colspan=”2″ width=”489″><span style=”color: #000000;”>28VDC</span></td>
</tr>
<tr>
<td width=”240″><span style=”color: #000000;”>Hold-up</span></td>
<td colspan=”2″ width=”489″><span style=”color: #000000;”>No Power Hold Up</span></td>
</tr>
<tr>
<td colspan=”3″ width=”716″><span style=”color: #000000;”>Physical Characteristics</span></td>
</tr>
<tr>
<td width=”240″><span style=”color: #000000;”>Enclosure</span></td>
<td colspan=”2″ width=”489″><span style=”color: #000000;”>Aluminum case</span></td>
</tr>
<tr>
<td width=”240″><span style=”color: #000000;”>Dimension (W * D * H)</span></td>
<td colspan=”2″ width=”489″><span style=”color: #000000;”>149mm (W) x 95mm (D) x 45mm (H) / 5.86in (W) x 3.74in (D) x 1.78in (H)</span></td>
</tr>
<tr>
<td width=”240″><span style=”color: #000000;”>Weight</span></td>
<td colspan=”2″ width=”489″><span style=”color: #000000;”>930g / 2.05lbs.</span></td>
</tr>
<tr>
<td width=”240″><span style=”color: #000000;”>Surface finish</span></td>
<td colspan=”2″ width=”489″><span style=”color: #000000;”>Powder paint on top of SurTec 650</span></td>
</tr>
<tr>
<td colspan=”3″ width=”716″><span style=”color: #000000;”>EMC/Enviromental</span></td>
</tr>
<tr>
<td width=”240″><span style=”color: #000000;”>Conducted Emission</span></td>
<td colspan=”2″ width=”489″><span style=”color: #000000;”>MIL-STD-461F: CE102, 10KHz – 10MHz, power leads</span></td>
</tr>
<tr>
<td width=”240″><span style=”color: #000000;”>Conducted Susceptibility</span></td>
<td colspan=”2″ width=”489″><span style=”color: #000000;”>MIL-STD-461F/G: CS101, Power Leads; CS114, Bulk Cable Injection, 10 KHz – 200</span>
<span style=”color: #000000;”>MHz; CS115, Bulk Cable Injection, 10 KHz – 200 MHz; CS116, Damped Sinusoidal Transients, Cables and Power Leads, 10 KHz – 100 MHz; CS118, Personnel Borne Electrostatic Discharge (ESD)</span></td>
</tr>
<tr>
<td width=”240″><span style=”color: #000000;”>Radiated Emission</span></td>
<td colspan=”2″ width=”489″><span style=”color: #000000;”>MIL-STD-461F: RE101, Magnetic Field, 30Hz – 100KHz, Army; RE102, Electric</span>
<span style=”color: #000000;”>Field</span></td>
</tr>
<tr>
<td width=”240″><span style=”color: #000000;”>Radiated Susceptibility</span></td>
<td colspan=”2″ width=”489″><span style=”color: #000000;”>MIL-STD-461F: RS103, 2MHz-40MHz, 200V/m</span></td>
</tr>
<tr>
<td width=”240″><span style=”color: #000000;”>Power input</span></td>
<td colspan=”2″ width=”489″><span style=”color: #000000;”>MIL-STD-1275E</span></td>
</tr>
<tr>
<td width=”240″><span style=”color: #000000;”>Operational Temperature</span></td>
<td colspan=”2″ width=”489″><span style=”color: #000000;”>MIL-STD-810G: 501.5, 502.5 and 503.5, [-40..+71]C<sup>◦</sup></span></td>
</tr>
<tr>
<td width=”240″><span style=”color: #000000;”>Storage Temperature</span></td>
<td colspan=”2″ width=”489″><span style=”color: #000000;”>MIL-STD-810G: 502.5, [-40..+85]C<sup>◦</sup></span></td>
</tr>
<tr>
<td width=”240″><span style=”color: #000000;”>Altitude</span></td>
<td colspan=”2″ width=”489″><span style=”color: #000000;”>MIL-STD-810G: 500.5, 85.000ft</span></td>
</tr>
<tr>
<td width=”240″><span style=”color: #000000;”>Operational vibration</span></td>
<td colspan=”2″ width=”489″><span style=”color: #000000;”>MIL-STD-810G: 514.6, procedure I (up to 10g)</span></td>
</tr>
<tr>
<td width=”240″><span style=”color: #000000;”>Shock</span></td>
<td colspan=”2″ width=”489″><span style=”color: #000000;”>MIL-STD-810G: 516.6, procedure V (40g, 11ms); 516.4, procedure 1 (30g, 11ms);</span></td>
</tr>
<tr>
<td width=”240″><span style=”color: #000000;”>Acceleration loads</span></td>
<td colspan=”2″ width=”489″><span style=”color: #000000;”>MIL-STD-810G: Method 513.6 (operational: 24g, ultimate load: 35.9g)</span></td>
</tr>
</tbody>
</table>
Related products
GROUND & SHIPBOARD ETHERNET SWITCHES
- Managed Military Switch with Grandmaster Clock
- 2xD38999 for 4×10/100/1000BASE-T
- GPIOs and 3 x coax for 4x 1G-T
- MIL Environmental & EMC Approved
FLIGHT-RATED ETHERNET SWITCHES
- Managed Aircraft switch with 2x D38999 connector
- Or 2x D38999 connector 24ZE35 for 12×10/100/1000BASE-T”
- Approved aircraft environmental & EMC
- 28VDC (22-32VDC)
FLIGHT-RATED ETHERNET SWITCHES
- Managed Military Switch & Router
- PTP 1588 Grand Master Clock
- 13xRJ45 for 13x 1G-T
- Complies with military environmental & EMC requirements
GROUND & SHIPBOARD ETHERNET SWITCHES
- Up to 49 x 10/100/1000Base-Tx ports in RJ45 connectors
- Up to 4 x 10gigabit ports in LC connectors
- Commercial Off the Shelf (COTS)
- Optional Embedded Services Router
MISSION MANAGEMENT
FLIGHT-RATED ETHERNET SWITCHES
- Managed Military Rack Switch
- PTP 1588 Grand Master Clock
- 49xRJ45 for 49x 1G-T + 2xRJ45 for 2x 10G-T + 1xSFP + for 1x 10G-X
- Approved aircraft environmental & EMC
GROUND & SHIPBOARD ETHERNET SWITCHES
- 12x1G; 12x10G-T; Optional 4x10G Fiber
- Other Configurations Available
- Managed Layer 3 Ethernet Switch
- TSN Compliant
- Embedded Services Router
FLIGHT-RATED ETHERNET SWITCHES
CR-6200 AER SERIES | 22pins D38999 – AIRCRAFT SWITCH & ROUTER
- Managed Aircraft switch and router with 10x D38999s for 20x 10/100/1000BASE-T
- 28VDC (22-32VDC)
- Approved for aircraft environmental and EMC requirements
- PTP TC/SC with PTP version translation (v1/v2) support